Article ID: 546
Last updated: 31 Mar, 2022
ProblemSome versions of the Smart Technologies Product Drivers can cause problems when a USB 3.0 controller is installed in the system. This has been verified on Windows 7 and the 2010 version of the Smart Technologies driver package. When you boot the system, the keboard and or mouse may be unresponsive until you remove them and then plug them back in. Removing the USB 3.0 controller monitor program does not resolve the problem. The problem has been seen on H61, B75, Q77 and H81 systems. CauseThe drivers themselves appear to cause system problems as they were not designed to be aware of USB 3.0 controllers. The issues are evident even if you are not using the USB 3.0 ports on the system. ResolutionEither seek updated drivers from Smart Technologies, or if you are not connecting the Smartboard / Smarttable to the problem system, just uninstall the Smart Technologies driver package from Control Panel. The rest of the Smart Technology software will continue to function without the driver package. Note: This problem is also described in the article USB 3.0 Controller Driver Issues and Work Around Summary.
Applies to:
This article was:
Article ID: 546
Last updated: 31 Mar, 2022
Revision: 4
Views: 6556
Posted: 18 Mar, 2016 by
Andrew Sharrad
Updated: 31 Mar, 2022 by
Andrew Sharrad
Also read
Also listed in
|